Closed loop current sensor based on the principle of Hall-effect. It can be used for
measuring AC,DC,pulsed and mixed current.
Electrical characteristics |
|
Type |
RTCSM025AY |
|
IPN |
Primary nominal input current |
25 |
A |
IP |
Measuring range of primary current |
0~±36 |
A |
ISN |
Secondary nominal output current |
25 |
mA |
KN |
Conversion ratio |
1-2-3-4:1000 |
|
RM |
Measuring resistance (VC=±15V) |
IP =±25A 54~360 |
IP =±36A 68~190 |
RM |
VC |
Supply voltage |
±12~±15(±5%) |
V |
IC |
Current consumption |
VC=±15V 10+Is |
mA |
VD |
Insulation voltage |
AC/50Hz/1min 2.5 |
kV |
εL |
Linearity |
<0.2 |
%FS |
X |
Accuracy |
TA=25℃ VC =±15V <±0.7 |
% |
IO |
Zero offset current |
TA=25℃ <±0.15 |
mA |
IOM |
Residual current |
IP→0 <±0.15 |
mA |
IOT |
Thermal drift of I0 |
IP=0 TA=-25~+70℃ <±0.5 |
mA |
TR |
Response time |
<1 |
μs |
f |
Frequency bandwidth(-1dB) |
DC~100 |
kHz |
TA |
Ambient operating temperature |
-25~+70 |
℃ |
TS |
Ambient storage temperature |
-40~+100 |
℃ |
RP |
Primary coil resistance |
TA=25℃ ≤1.25 |
mΩ |
RS |
Secondary coil resistance |
TA=70℃ 40 |
Ω |
RIS |
Isolation resistance |
TA=25℃ ≥1500 |
MΩ |
|
Standard |
Q/3201CHGL02-2007 |
|
Dimensions of drawing (mm) Connection |
|
Remarks |
·Incorrect connection may lead to the damage of the sensor.
·ISN is positive when the IP flows in the direction of the arrow. |