photoelectricity switch
RTCS2500KF2 Hall-effect Current Sensor Series

Open loop current sensor based on the principle of Hall-effect. It can be used for measuring AC,DC,pulsed and mixed current.      

Electrical characteristics

 

Type

RTCS500KF2

RTCS1000KF2

RTCS1500KF2

RTCS2000KF2

RTCS2000KF2

 

IPN

Primary nominal input current

500

1000

1500

2000

2500

A

IP

Measuring range of primary current                        

0~±1000

0~±2000

0~±3000

0~±3000

0~±3000

A

VOUT

Nominal output voltage

4±1%

V

VC

Supply voltage

±12~±15(±5%)

V

IC

Current consumption

VC=±15V                      <25

mA

VD

Insulation voltage

AC/50Hz/1min                   6

kV

εL

Linearity

<1

%FS

VO

Offset voltage

TA=25℃                      <±25

mV

VOM

Residual voltage                                 

IPN→0                        <±30

mV

VOT

Thermal drift of V0                               

IP=0  TA=25~+85℃           <±1

mV/℃

TR

Response time

<7

μs

f

Frequency bandwidth(-3dB)

DC~20

kHz

TA

Ambient operating temperature                 

25~+85

TS

Ambient storage temperature                 

40~+100

RL

Load resistance                   

≥10

KΩ

 

Standard

Q/3201CHGL02-2007

 

Dimensions of drawing (mm)

文本框:  Elucidation:  1: +15V  2: 15V  3: VOUT  4: 0V(GND)  OFS: Zero adjustment  GIN: Gain adjustment
( Red: +15V  Blue: -15V  Yellow: VOUT  Black: 0V )

Remarks

·Incorrect connection may lead to the damage of the sensor.
·VOUT is positive when the IP flows in the direction of the arrow.

 



Copyright©Rongtech Industry (Shanghai) Inc.,