RTCS040G
RTCS040G Hall-effect Current Sensor Series
Open loop current sensor based on the principle of Hall-effect. It can be used for measuring AC,DC,pulsed and mixed current.
Electrical characteristics |
|
Type |
RTCS010G |
RTCS020G |
RTCS030G |
RTCS040G |
|
IPN |
Primary nominal input current |
10 |
20 |
30 |
40 |
A |
IP |
Measuring range of primary current |
0~±20 |
0~±40 |
0~±60 |
0~±80 |
A |
VOUT |
Nominal output voltage |
1±1% |
V |
VC |
Supply voltage |
±12~±15(±5%) |
V |
IC |
Current consumption |
VC=±15V <20 |
mA |
VD |
Insulation voltage |
AC/50Hz/1min 2.5 |
kV |
εL |
Linearity |
<1 |
%FS |
VO |
Offset voltage |
TA=25℃ <±20 |
mV |
VOM |
Residual voltage |
IPN→0 <±10 |
mV |
VOT |
Thermal drift of V0 |
IP=0 TA=-25~+70℃ <±1 |
mV/℃ |
TR |
Response time |
≤3 |
μs |
f |
Frequency bandwidth(-3dB) |
DC~20 |
kHz |
TA |
Ambient operating temperature |
–25~+70 |
℃ |
TS |
Ambient storage temperature |
–40~+85 |
℃ |
RL |
Load resistance |
≥10 |
KΩ |
|
Standard |
Q/3201CHGL02-2007 |
|
Dimensions of drawing (mm) |

Elucidation: 1:+15V 2:0V(GND) 3:VOUT 4:–15V |
Remarks |
·Incorrect connection may lead to the damage of the sensor.
·VOUT is positive when the IP flows in the direction of the arrow. |
|